Membrane cell electrolysis

SPECIFICATIONS AND TECHNICAL INFORMATION

ELECTROLYSIS DEVICE WITH MEMBRANE CELL UNDER WATER

Type 24Type 48Type 100
Nominal powerg Cl2 / h2448100
Water consumptionl / h1,01,05,0
Salt consumptionkg / Tag3610
Solution concentrationg Cl2 / l0,60,80,8
Hydrogen at 100%l / h102050
Flow rate through float chamberl / h4060120
     
PVC MOUNTING PANEL    
Heightmm740740740
Widthmm755820820
Depthmm300300300
Weightkg253035
     
SALT DISSOLVING TANK    
Contents of salt dissolving tankl909090
Hydrogen outletkg757575
     
CONNECTIONS    
WasserstoffabgangDN101010
Power connectionV / AC230230230
Electrical power consumptionVA100260520

Areas of application

  • Outdoor swimming pools privat / public
  • Indoor swimming pools privat / public
  • Therapy baths
  • Whirlpools

The electrolysis unit is connected to the pool water and does not require a fresh water connection. Part of the pool water is used to absorb the resulting disinfectant, which is fed into the circulation line by means of an injector. This means that no additional dosing pump is required.

The extraction is monitored and production is switched off if the quantity falls below a minimum level. As the cell is located under water, there is no danger from escaping chlorine. There is also an optional chlorine gas sensor for monitoring the room air. The system can be mounted using the optionally available wall brackets and the salt dissolving tank can be placed underneath. This minimises the space required and makes installation easy.

ELECTROLYSIS UNIT WITH FREE-HANGING CELL

Typ 250Typ 500
Nominal powerg Cl2 / h250500
Water consumptionl / h12,525
Salt consumptionkg / Tag2550
Solution concentrationg Cl2 / l0,80,8
Hydrogen at 100%l / h125250
Flow rate through float chamberl / h300600
    
STEEL MOUNTING PANEL   
Heightmm2.0102.010
Widthmm1.3001.020
Depthmm500500
Weightkg5045
    
SALT DISSOLVING TANK   
Contents of salt dissolving tankl90210
Hydrogen outletkg75175
    
CONNECTIONS   
Hydrogen outletDN5050
Power connectionV / AC400400
Electrical power consumptionkVA2,35,0

Areas of application

  • Outdoor swimming pools public
  • Indoor swimming pools public
  • Therapy baths
  • School swimming pools

The electrolysis system is connected to fresh water and the pool water. The pool water is used to absorb the resulting disinfectant, which is fed into the circulation line by means of an injector. This means that no additional dosing pump is required.

The extraction is monitored and production is switched off if the volume falls below a minimum level. The fresh water is used exclusively for production and is softened to a value between 0 and 1° dH using a separate softener. A pressure reducer reduces the upstream pressure of the fresh water to 1 bar and ensures constant conditions within the electrolytic cell. The system is pre-assembled on a free-standing frame. This significantly reduces the installation work on site. It has a pre-installed chlorine gas sensor to ensure safe operation of the system. The hydrogen produced in the cathode chamber is channelled outside. (for type 200 by means of a fan)

Your advantages at a glance.

  • No chlorine odour
  • No handling of hazardous chemicals
  • No stinging eyes
  • No irritation of mucous membranes
  • No salinisation
  • Maximum and reliable disinfection effect
  • Low operating costs
  • State-of-the-art membrane cell technology
  • Made in Germany

Our team of experts will be happy to help you plan the next steps. Whether it’s a swimming pool, whirlpool or therapy pool – we have the experience and expertise to get your project on the right track.

Feel free to contact us today.