Membrane cell electrolysis
SPECIFICATIONS AND TECHNICAL INFORMATION
ELECTROLYSIS DEVICE WITH MEMBRANE CELL UNDER WATER
Type 24 | Type 48 | Type 100 | ||
---|---|---|---|---|
Nominal power | g Cl2 / h | 24 | 48 | 100 |
Water consumption | l / h | 1,0 | 1,0 | 5,0 |
Salt consumption | kg / Tag | 3 | 6 | 10 |
Solution concentration | g Cl2 / l | 0,6 | 0,8 | 0,8 |
Hydrogen at 100% | l / h | 10 | 20 | 50 |
Flow rate through float chamber | l / h | 40 | 60 | 120 |
PVC MOUNTING PANEL | ||||
Height | mm | 740 | 740 | 740 |
Width | mm | 755 | 820 | 820 |
Depth | mm | 300 | 300 | 300 |
Weight | kg | 25 | 30 | 35 |
SALT DISSOLVING TANK | ||||
Contents of salt dissolving tank | l | 90 | 90 | 90 |
Hydrogen outlet | kg | 75 | 75 | 75 |
CONNECTIONS | ||||
Wasserstoffabgang | DN | 10 | 10 | 10 |
Power connection | V / AC | 230 | 230 | 230 |
Electrical power consumption | VA | 100 | 260 | 520 |
Areas of application
- Outdoor swimming pools privat / public
- Indoor swimming pools privat / public
- Therapy baths
- Whirlpools

The electrolysis unit is connected to the pool water and does not require a fresh water connection. Part of the pool water is used to absorb the resulting disinfectant, which is fed into the circulation line by means of an injector. This means that no additional dosing pump is required.
The extraction is monitored and production is switched off if the quantity falls below a minimum level. As the cell is located under water, there is no danger from escaping chlorine. There is also an optional chlorine gas sensor for monitoring the room air. The system can be mounted using the optionally available wall brackets and the salt dissolving tank can be placed underneath. This minimises the space required and makes installation easy.
ELECTROLYSIS UNIT WITH FREE-HANGING CELL
Typ 250 | Typ 500 | ||
---|---|---|---|
Nominal power | g Cl2 / h | 250 | 500 |
Water consumption | l / h | 12,5 | 25 |
Salt consumption | kg / Tag | 25 | 50 |
Solution concentration | g Cl2 / l | 0,8 | 0,8 |
Hydrogen at 100% | l / h | 125 | 250 |
Flow rate through float chamber | l / h | 300 | 600 |
STEEL MOUNTING PANEL | |||
Height | mm | 2.010 | 2.010 |
Width | mm | 1.300 | 1.020 |
Depth | mm | 500 | 500 |
Weight | kg | 50 | 45 |
SALT DISSOLVING TANK | |||
Contents of salt dissolving tank | l | 90 | 210 |
Hydrogen outlet | kg | 75 | 175 |
CONNECTIONS | |||
Hydrogen outlet | DN | 50 | 50 |
Power connection | V / AC | 400 | 400 |
Electrical power consumption | kVA | 2,3 | 5,0 |
Areas of application
- Outdoor swimming pools public
- Indoor swimming pools public
- Therapy baths
- School swimming pools

The electrolysis system is connected to fresh water and the pool water. The pool water is used to absorb the resulting disinfectant, which is fed into the circulation line by means of an injector. This means that no additional dosing pump is required.
The extraction is monitored and production is switched off if the volume falls below a minimum level. The fresh water is used exclusively for production and is softened to a value between 0 and 1° dH using a separate softener. A pressure reducer reduces the upstream pressure of the fresh water to 1 bar and ensures constant conditions within the electrolytic cell. The system is pre-assembled on a free-standing frame. This significantly reduces the installation work on site. It has a pre-installed chlorine gas sensor to ensure safe operation of the system. The hydrogen produced in the cathode chamber is channelled outside. (for type 200 by means of a fan)
Your advantages at a glance.
- No chlorine odour
- No handling of hazardous chemicals
- No stinging eyes
- No irritation of mucous membranes
- No salinisation
- Maximum and reliable disinfection effect
- Low operating costs
- State-of-the-art membrane cell technology
- Made in Germany
Our team of experts will be happy to help you plan the next steps. Whether it’s a swimming pool, whirlpool or therapy pool – we have the experience and expertise to get your project on the right track.